Last week, Team82 published the inaugural installment of its new Biannual ICS Risk & Vulnerability Report, which offers an in-depth assessment of all ICS vulnerabilities disclosed during the first half of the year (1H 2020), the challenges they pose to security practitioners, and what conclusions can be drawn from publicly available data. For more insight into the report's research findings and the implications for those tasked with defending OT environments, join Claroty Chief Product Officer Grant Geyer for our upcoming webinar to be held this Thursday, Aug. 27, at 10 a.m. EST. Click here to register.
The infographics below offer some visual perspective into key statistics from the Claroty Biannual ICS Risk & Vulnerability Report, 1H 2020, which will be discussed in greater detail during the webinar:
The webinar will also offer additional insights into the vendors, products, sectors, and regions most affected by recently discovered ICS vulnerabilities, potential impacts and other characteristics of these vulnerabilities, and how the ICS risk & vulnerability landscape has changed since 1H 2019.
CWE-547 USE OF HARD-CODED, SECURITY-RELEVANT CONSTANTS:
Optigo Networks Visual BACnet Capture Tool and Optigo Visual Networks Capture Tool version 3.1.2rc11 are vulnerable to an attacker impersonating the web application service and mislead victim clients.
Optigo Networks recommends users to upgrade to the following:
CVSS v3: 7.5
CWE-288 AUTHENTICATION BYPASS USING AN ALTERNATE PATH OR CHANNEL:
Optigo Networks Visual BACnet Capture Tool and Optigo Visual Networks Capture Tool version 3.1.2rc11 contain an exposed web management service that could allow an attacker to bypass authentication measures and gain controls over utilities within the products.
Optigo Networks recommends users to upgrade to the following:
CVSS v3: 9.8
CWE-547 USE OF HARD-CODED, SECURITY-RELEVANT CONSTANTS:
Optigo Networks Visual BACnet Capture Tool and Optigo Visual Networks Capture Tool version 3.1.2rc11 contain a hard coded secret key. This could allow an attacker to generate valid JWT (JSON Web Token) sessions.
Optigo Networks recommends users to upgrade to the following:
CVSS v3: 7.5
CWE-912 HIDDEN FUNCTIONALITY:
The "update" binary in the firmware of the affected product sends attempts to mount to a hard-coded, routable IP address, bypassing existing device network settings to do so. The function triggers if the 'C' button is pressed at a specific time during the boot process. If an attacker is able to control or impersonate this IP address, they could upload and overwrite files on the device.
Per FDA recommendation, CISA recommends users remove any Contec CMS8000 devices from their networks.
If asset owners cannot remove the devices from their networks, users should block 202.114.4.0/24 from their networks, or block 202.114.4.119 and 202.114.4.120.
Please note that this device may be re-labeled and sold by resellers.
Read more here: Do the CONTEC CMS8000 Patient Monitors Contain a Chinese Backdoor? The Reality is More Complicated….
CVSS v3: 7.5
CWE-295 IMPROPER CERTIFICATE VALIDATION:
The affected product is vulnerable due to failure of the update mechanism to verify the update server's certificate which could allow an attacker to alter network traffic and carry out a machine-in-the-middle attack (MITM). An attacker could modify the server's response and deliver a malicious update to the user.
Medixant recommends users download the v2025.1 or later version of their software.
CVSS v3: 5.7